Petroleum power plant, Maryland

Easton 2 petroleum power plant, Maryland

Easton 2 is a 38.8 MW petroleum power plant in Talbot County, Maryland, operated by Easton Utilities Comm, and it generated 4,367 MWh in 2025 (Forms EIA-860 and EIA-923). Its capacity factor sits at the 73rd percentile of U.S. petroleum plants. By 2025 generation it ranks 8,422nd of 12,977 U.S. plants.

Latest data: August 2026; data loaded .

38.8 MWNameplate capacity
1%Capacity factor, 2025, 73rd percentile, on 37 MW net summer
8,422ndU.S. rank by generation, 2025
35 yearsAverage generator age, by MW

How hard does the Easton 2 plant run compared with other petroleum plants?

The Easton 2 plant had a capacity factor of 1% in 2025 on 37 MW of net summer capacity, the 73rd percentile of the 143 U.S. petroleum plants with at least 20 MW. The typical petroleum plant reached 1%. That equals about 5 days at full output out of 365.

0%Shaded: the middle half of petroleum plants. Mark: this plant.105%

Capacity factor, 2025
MeasureCapacity factor
Easton 21%
Petroleum plants, 75th percentile1%
Petroleum plants, median1%
Petroleum plants, 25th percentile0%

Source: EIA Forms EIA-860 and EIA-923, 2025. Capacity factor is net generation divided by capacity times the hours in the year, using net summer capacity, as EIA does. Values above 105% are left out of the comparison.

Is the Easton 2 plant generating more or less than last year?

Easton 2 generated 4,367 MWh in 2025; EIA reports no 2024 total to compare. Through August 2026 it is running 49.5% ahead of the same months of 2025. 2024 has output for only 3 months, so the two years are not compared.

13 months show net generation below zero, when the plant used more power than it sent out, so the months are listed below rather than charted.

Net generation by period
PeriodMWh
2024-674
20254,367
2026 through August4,526
2025, same months3,028
Monthly generation, Jan 2024 to Aug 2026
MonthMWh
August 202620
July 2026454
June 2026191
May 2026135
April 202613
March 20260
February 20261,268
January 20262,445
December 20251,489
November 2025-110
October 2025-40
September 20250
August 202557
July 2025729
June 2025634
May 20250
April 2025203
March 20251,480
February 2025-10
January 2025-65
December 2024-137
November 2024-78
October 2024-88
September 2024-91
August 2024-76
July 2024142
June 20247
May 2024-77
April 2024-86
March 2024-110
February 2024-89
January 20249

Source: EIA Form EIA-923, through August 2026.

How much of Maryland's electricity comes from the Easton 2 plant?

Easton 2 made 0.0% of the 37,475,103 MWh reported by Maryland plants in 2025, from 0.3% of the state's 13,377 MW of capacity. Its share of output is smaller than its share of capacity. By capacity it is the 31st largest of 236 plants in Maryland, the 4,148th largest of 14,327 in the U.S. and the 117th largest of 861 petroleum plants. By 2025 generation it is the 70th largest of 226 generating plants in the state.

Easton 2 within Maryland, 2025
MeasureThis plantMarylandShare
Capacity (MW)3913,3770.3%
Generation (MWh)4,36737,475,1030.0%
Petroleum capacity (MW)391,4782.6%

Source: EIA Forms EIA-860 and EIA-923, 2025. State totals add up the plants in these forms, including net use by storage.

How old are the generators at the Easton 2 plant, and when do they retire?

8 operable generators total 38.8 MW, with an average age of 35 years weighted by capacity at the end of 2025. No operable generator has a planned retirement date on Form EIA-860.

Operable generators by decade in service
Entered serviceUnitsMWSharePlanned retirement
1970s21232%none reported
1980s21332%none reported
1990s238%none reported
2000s21128%none reported
Every generator, 8 in all
UnitStatusTechnologyMWIn servicePlanned retirement
21OperatingPetroleum Liquids61978n/a
22OperatingPetroleum Liquids61978n/a
23OperatingPetroleum Liquids61989n/a
24OperatingPetroleum Liquids61989n/a
201OperatingPetroleum Liquids21995n/a
202OperatingPetroleum Liquids21995n/a
203OperatingPetroleum Liquids52004n/a
204OperatingPetroleum Liquids52004n/a

Source: EIA Form EIA-860, Generator, 2025 final.

Who owns the Easton 2 plant?

EIA lists no joint owners for Easton 2. Easton Utilities Comm operates the plant.

Source: EIA Form EIA-860, Owner, 2025 final.

What does Easton Utilities Comm charge homes?

Easton Utilities Comm, the operator of Easton 2, had an average residential price of 15.18¢ per kWh and an average bill of $159 a month in 2025, 22% below the Maryland average of 19.53¢.

Average residential price and bill, 2025
MeasurePriceMonthly billAgainst Maryland
Easton Utilities Comm15.18¢$15922% lower
Maryland average19.53¢$184
U.S. average17.23¢$15112% lower

Source: EIA Form EIA-861, final 2025. Average price is revenue divided by sales. It is what the seller's customers paid on average, not the cost of this plant's output.

Where is the Easton 2 plant?

Easton 2 is in Easton, Talbot County, Maryland, at 38.7950° N, 76.0700° W. It sits in the PJM Interconnection, LLC balancing area (NERC region RFC).

Source: EIA Form EIA-860, Plant, 2025 final.

Which petroleum plants in Maryland are similar in size?

Maryland has 10 operable petroleum plants with 1,478 MW of capacity, and Easton 2's 38.8 MW is 3% of that.

Petroleum plants in Maryland around this size
PlantCountyMW2025 MWh
Easton 2Talbot394,367
EastonTalbot312,704

Source: EIA Forms EIA-860 and EIA-923, 2025.