Princeton University Cogeneration is a 32.1 MW power plant, 16.6 MW of it solar, in Mercer County, New Jersey, operated by Trustees of Princeton University, and it generated 77,202 MWh in 2025 (Forms EIA-860 and EIA-923). That is 0.1% of the generation reported in New Jersey, and its capacity factor sits at the 11th percentile of U.S. solar plants. By 2025 generation it ranks 3,684th of 12,977 U.S. plants.

Latest data: August 2026; data loaded .

32.1 MWNameplate capacity
14%Capacity factor, 2025, solar units, 11th percentile, on 16.6 MW net summer
0.1%Of NJ generation, 2025
17 yearsAverage generator age, by MW

How hard does the Princeton University Cogeneration plant run compared with other solar plants?

The Princeton University Cogeneration plant's solar units had a capacity factor of 14% in 2025 on 16.6 MW of net summer capacity, the 11th percentile of the 1,298 U.S. solar plants with at least 20 MW. The typical solar plant reached 23%. That equals about 52 days at full output out of 365.

0%Shaded: the middle half of solar plants. Mark: this plant.105%

Capacity factor, 2025
MeasureCapacity factor
Princeton University Cogeneration14%
Solar plants, 75th percentile27%
Solar plants, median23%
Solar plants, 25th percentile20%

Source: EIA Forms EIA-860 and EIA-923, 2025. Capacity factor is net generation divided by capacity times the hours in the year, using net summer capacity, as EIA does, for its solar generators only. Values above 105% are left out of the comparison.

Is the Princeton University Cogeneration plant generating more or less than last year?

Generation at Princeton University Cogeneration rose 41.8% from 2024 to 2025, from 54,460 MWh to 77,202 MWh. Through August 2026 it is running 6.9% ahead of the same months of 2025.

Net generation by period
PeriodMWh
202454,460
202577,202
2026 through August55,542
2025, same months51,950
Monthly generation, Jan 2024 to Aug 2026
MonthMWh
August 20268,452
July 20269,187
June 20267,928
May 20267,610
April 20262,440
March 20266,451
February 20265,900
January 20267,574
December 20258,368
November 20256,055
October 20254,482
September 20256,347
August 20258,324
July 20259,546
June 20258,448
May 20254,043
April 20252,080
March 20252,753
February 20257,653
January 20259,103
December 20247,309
November 20241,517
October 20242,104
September 20241,760
August 20246,845
July 20248,572
June 20246,670
May 20243,469
April 20247,249
March 20241,773
February 20244,048
January 20243,144

Source: EIA Form EIA-923, through August 2026.

How much of New Jersey's electricity comes from the Princeton University Cogeneration plant?

Princeton University Cogeneration made 0.1% of the 60,873,773 MWh reported by New Jersey plants in 2025, from 0.2% of the state's 18,172 MW of capacity. Its share of output is smaller than its share of capacity. By capacity it is the 31st largest of 416 plants in New Jersey, the 4,299th largest of 14,327 in the U.S. and the 1,350th largest of 7,223 solar plants on its solar units alone. By 2025 generation it is the 27th largest of 387 generating plants in the state.

Princeton University Cogeneration within New Jersey, 2025
MeasureThis plantNew JerseyShare
Capacity (MW)3218,1720.2%
Generation (MWh)77,20260,873,7730.1%
Solar capacity (MW)171,2351.3%

Source: EIA Forms EIA-860 and EIA-923, 2025. State totals add up the plants in these forms, including net use by storage.

How old are the generators at the Princeton University Cogeneration plant, and when do they retire?

5 operable generators total 32.1 MW, with an average age of 17 years weighted by capacity at the end of 2025. No operable generator has a planned retirement date on Form EIA-860.

Operable generators by decade in service
Entered serviceUnitsMWSharePlanned retirement
1990s11648%none reported
2010s1514%none reported
2020s31238%none reported
Every generator, 5 in all
UnitStatusTechnologyMWIn servicePlanned retirement
GT1OperatingNatural Gas Fired Combustion Turbine161996n/a
PV1OperatingSolar Photovoltaic52012n/a
PV2OperatingSolar Photovoltaic12021n/a
PV3OperatingSolar Photovoltaic112022n/a
PV4OperatingSolar Photovoltaic02022n/a

Source: EIA Form EIA-860, Generator, 2025 final.

Who owns the Princeton University Cogeneration plant?

2 owners report shares in Princeton University Cogeneration; Tiger Solar Partners, LLC holds the largest named share, 37.7% or about 12.1 MW. Trustees of Princeton University operates the plant. The listed shares add up to 51.7% of capacity; generators without joint owners are not on this list.

Reported ownership of operable capacity
OwnerShareMW2025 MWh, by share
Tiger Solar Partners, LLC37.7%1229,097
Key Government Finance, Inc.14.0%510,824

Source: EIA Form EIA-860, Owner, 2025 final. MW and MWh by share multiply the plant totals by each owner's percentage.

What fuels does the Princeton University Cogeneration plant use?

Princeton University Cogeneration has capacity on 2 fuels: 52% solar and 48% natural gas. In 2025, solar made 27% of its output.

Capacity and 2025 generation by fuel
FuelMWShare2025 MWh
Solar1751.7%20,686
Natural gas1648.3%55,676

Source: EIA Forms EIA-860 and EIA-923, 2025.

Where is the Princeton University Cogeneration plant?

Princeton University Cogeneration is in Princeton, Mercer County, New Jersey, at 40.3414° N, 74.6572° W. It sits in the PJM Interconnection, LLC balancing area (NERC region RFC).

Source: EIA Form EIA-860, Plant, 2025 final.

Which solar plants in New Jersey are similar in size?

New Jersey has 334 operable solar plants with 1,235 MW of capacity, and Princeton University Cogeneration's 16.6 MW is 1% of that.

Solar plants in New Jersey around this size
PlantCountyMW2025 MWh
Mount Olive Solar FarmMorris2031,522
PilesgroveSalem1812,102
KDC Solar PR1, LLCOcean1727,649
Princeton University CogenerationMercer1720,686
Tinton Falls Solar FarmMonmouth16n/a
Foul Rift Solar FarmWarren1516,924
Parker Road SolarMorris156,643