Skip to main content
RateWatt

Biomass power plant, South Carolina

Sylvamo Corporation Eastover Facility, South Carolina

Sylvamo Corporation Eastover Facility is a 110 MW biomass power plant in Richland County, South Carolina, operated by Sylvamo Corporation-Eastover, and it generated 564,480 MWh in 2025 (Forms EIA-860 and EIA-923). That is 0.5% of the generation reported in South Carolina, and its capacity factor sits at the 64th percentile of U.S. biomass plants. By 2025 generation it ranks 1,200th of 12,977 U.S. plants.

Latest data: August 2026; data loaded .

110 MWNameplate capacity
56%Capacity factor, 2025, 64th percentile, on 103 MW net summer
0.5%Of SC generation, 2025
37 yearsAverage generator age, by MW

How hard does the Sylvamo Corporation Eastover Facility plant run compared with other biomass plants?

The Sylvamo Corporation Eastover Facility plant had a capacity factor of 56% in 2025 on 103 MW of net summer capacity, the 64th percentile of the 167 U.S. biomass plants with at least 20 MW. The typical biomass plant reached 48%. That equals about 206 days at full output out of 365.

0%Shaded: the middle half of biomass plants. Mark: this plant.105%

Capacity factor, 2025
MeasureCapacity factor
Sylvamo Corporation Eastover Facility56%
Biomass plants, 75th percentile65%
Biomass plants, median48%
Biomass plants, 25th percentile35%

Source: EIA Forms EIA-860 and EIA-923, 2025. Capacity factor is net generation divided by capacity times the hours in the year, using net summer capacity, as EIA does. Values above 105% are left out of the comparison.

Is the Sylvamo Corporation Eastover Facility plant generating more or less than last year?

Generation at Sylvamo Corporation Eastover Facility rose 8.5% from 2024 to 2025, from 520,341 MWh to 564,480 MWh. Through August 2026 it is running 5.8% behind the same months of 2025.

Net generation by period
PeriodMWh
2024520,341
2025564,480
2026 through August357,134
2025, same months379,167
Monthly generation, Jan 2024 to Aug 2026
MonthMWh
August 202647,608
July 202645,000
June 202643,327
May 202643,635
April 202643,742
March 202643,007
February 202646,183
January 202644,632
December 202550,998
November 202539,639
October 202547,786
September 202546,890
August 202545,971
July 202546,050
June 202547,762
May 202551,034
April 202548,849
March 202546,288
February 202546,286
January 202546,927
December 202443,144
November 202419,107
October 202431,770
September 202446,382
August 202447,044
July 202445,183
June 202447,318
May 202448,298
April 202449,453
March 202441,122
February 202448,552
January 202452,968

Source: EIA Form EIA-923, through August 2026.

How much of South Carolina's electricity comes from the Sylvamo Corporation Eastover Facility plant?

Sylvamo Corporation Eastover Facility made 0.5% of the 103,930,530 MWh reported by South Carolina plants in 2025, from 0.4% of the state's 27,220 MW of capacity. Its share of output is 1.3 times its share of capacity. By capacity it is the 32nd largest of 215 plants in South Carolina, the 2,453rd largest of 14,327 in the U.S. and the 12th largest of 585 biomass plants. By 2025 generation it is the 18th largest of 197 generating plants in the state.

Sylvamo Corporation Eastover Facility within South Carolina, 2025
MeasureThis plantSouth CarolinaShare
Capacity (MW)11027,2200.4%
Generation (MWh)564,480103,930,5300.5%
Biomass capacity (MW)11049122.3%

Source: EIA Forms EIA-860 and EIA-923, 2025. State totals add up the plants in these forms, including net use by storage.

How old are the generators at the Sylvamo Corporation Eastover Facility plant, and when do they retire?

2 operable generators total 110 MW, with an average age of 37 years weighted by capacity at the end of 2025. No operable generator has a planned retirement date on Form EIA-860.

Operable generators by decade in service
Entered serviceUnitsMWSharePlanned retirement
1980s14844%none reported
1990s16156%none reported
Every generator, 2 in all
UnitStatusTechnologyMWIn servicePlanned retirement
GEN1OperatingWood/Wood Waste Biomass481984n/a
GEN2OperatingWood/Wood Waste Biomass611991n/a

Source: EIA Form EIA-860, Generator, 2025 final.

Who owns the Sylvamo Corporation Eastover Facility plant?

EIA lists no joint owners for Sylvamo Corporation Eastover Facility. Sylvamo Corporation-Eastover operates the plant.

Source: EIA Form EIA-860, Owner, 2025 final.

Where is the Sylvamo Corporation Eastover Facility plant?

Sylvamo Corporation Eastover Facility is in Eastover, Richland County, South Carolina, at 33.8872° N, 80.6397° W. It sits in the Dominion Energy South Carolina balancing area (NERC region SERC).

Source: EIA Form EIA-860, Plant, 2025 final.

Which biomass plants in South Carolina are similar in size?

South Carolina has 16 operable biomass plants with 491 MW of capacity, and Sylvamo Corporation Eastover Facility's 110 MW is 22% of that.

Biomass plants in South Carolina around this size
PlantCountyMW2025 MWh
Sylvamo Corporation Eastover FacilityRichland110509,771
International Paper Georgetown MillGeorgetown960
Florence MillFlorence92359,375

Source: EIA Forms EIA-860 and EIA-923, 2025.