Skip to main content
RateWatt

Natural gas power plant, Missouri

Trigen St. Louis natural gas power plant, Missouri

Trigen St. Louis is a 34.2 MW natural gas power plant in St Louis County, Missouri, operated by Centerstream STL, LLC, and it generated 48,300 MWh in 2025 (Forms EIA-860 and EIA-923). That is 0.1% of the generation reported in Missouri, and its capacity factor sits at the 44th percentile of U.S. natural gas plants. By 2025 generation it ranks 4,138th of 12,977 U.S. plants.

Latest data: August 2026; data loaded .

34.2 MWNameplate capacity
17%Capacity factor, 2025, 44th percentile, on 33.4 MW net summer
0.1%Of MO generation, 2025
25 yearsAverage generator age, by MW

How hard does the Trigen St. Louis plant run compared with other natural gas plants?

The Trigen St. Louis plant had a capacity factor of 17% in 2025 on 33.4 MW of net summer capacity, the 44th percentile of the 1,236 U.S. natural gas plants with at least 20 MW. The typical natural gas plant reached 22%. That equals about 60 days at full output out of 365.

0%Shaded: the middle half of natural gas plants. Mark: this plant.105%

Capacity factor, 2025
MeasureCapacity factor
Trigen St. Louis17%
Natural gas plants, 75th percentile56%
Natural gas plants, median22%
Natural gas plants, 25th percentile6%

Source: EIA Forms EIA-860 and EIA-923, 2025. Capacity factor is net generation divided by capacity times the hours in the year, using net summer capacity, as EIA does. Values above 105% are left out of the comparison.

Is the Trigen St. Louis plant generating more or less than last year?

Generation at Trigen St. Louis fell 42.8% from 2024 to 2025, from 84,435 MWh to 48,300 MWh. Through August 2026 it is running 68.3% behind the same months of 2025.

Net generation by period
PeriodMWh
202484,435
202548,300
2026 through August15,306
2025, same months48,300
Monthly generation, Jan 2024 to Aug 2026
MonthMWh
August 20268,765
July 20266,541
June 20260
May 20260
April 20260
March 20260
February 20260
January 20260
December 20250
November 20250
October 20250
September 20250
August 20250
July 20256,723
June 20257,387
May 20256,123
April 20254,078
March 20256,710
February 20257,544
January 20259,735
December 20249,497
November 20248,518
October 20244,696
September 20247,939
August 20247,129
July 20248,130
June 20247,402
May 20244,508
April 20246,883
March 20247,093
February 20245,534
January 20247,106

Source: EIA Form EIA-923, through August 2026.

How much of Missouri's electricity comes from the Trigen St. Louis plant?

Trigen St. Louis made 0.1% of the 71,443,096 MWh reported by Missouri plants in 2025, from 0.1% of the state's 23,215 MW of capacity. Its share of output is smaller than its share of capacity. By capacity it is the 69th largest of 137 plants in Missouri, the 4,258th largest of 14,327 in the U.S. and the 1,187th largest of 1,962 natural gas plants. By 2025 generation it is the 52nd largest of 122 generating plants in the state.

Trigen St. Louis within Missouri, 2025
MeasureThis plantMissouriShare
Capacity (MW)3423,2150.1%
Generation (MWh)48,30071,443,0960.1%
Natural gas capacity (MW)346,0850.6%

Source: EIA Forms EIA-860 and EIA-923, 2025. State totals add up the plants in these forms, including net use by storage.

How old are the generators at the Trigen St. Louis plant, and when do they retire?

6 operable generators total 34.2 MW, with an average age of 25 years weighted by capacity at the end of 2025. No operable generator has a planned retirement date on Form EIA-860.

Operable generators by decade in service
Entered serviceUnitsMWSharePlanned retirement
1990s51647%none reported
2000s11853%none reported
Every generator, 6 in all
UnitStatusTechnologyMWIn servicePlanned retirement
CT-1OperatingNatural Gas Fired Combined Cycle61999n/a
CT-2OperatingNatural Gas Fired Combined Cycle61999n/a
IC-1OperatingNatural Gas Internal Combustion Engine11999n/a
ST-4OperatingNatural Gas Steam Turbine21999n/a
ST-5OperatingNatural Gas Steam Turbine21999n/a
ST-3OperatingNatural Gas Fired Combined Cycle182000n/a

Source: EIA Form EIA-860, Generator, 2025 final.

Who owns the Trigen St. Louis plant?

EIA lists no joint owners for Trigen St. Louis. Centerstream STL, LLC operates the plant.

Source: EIA Form EIA-860, Owner, 2025 final.

Where is the Trigen St. Louis plant?

Trigen St. Louis is in St Louis, St Louis County, Missouri, at 38.6359° N, 90.1809° W. It sits in the Midcontinent Independent Transmission System Operator, Inc. balancing area (NERC region SERC).

Source: EIA Form EIA-860, Plant, 2025 final.

Which natural gas plants in Missouri are similar in size?

Missouri has 34 operable natural gas plants with 6,085 MW of capacity, and Trigen St. Louis' 34.2 MW is 1% of that.

Natural gas plants in Missouri around this size
PlantCountyMW2025 MWh
Station HJackson4312,343
CarthageJasper42-190
HigginsvilleLafayette401,706
Trigen St. LouisSt Louis3448,300
Poplar Bluff Generating StationButler34627
Marshall (MO)Saline281,209
Fredericktown Energy CenterMadison284,239

Source: EIA Forms EIA-860 and EIA-923, 2025.