Natural gas power plant, New Mexico
Cunningham natural gas power plant, New Mexico
Cunningham is a 444 MW natural gas power plant in Lea County, New Mexico, operated by Southwestern Public Service Co, and it generated 1,792,031 MWh in 2025 (Forms EIA-860 and EIA-923). That is 4.6% of the generation reported in New Mexico, and its capacity factor sits at the 72nd percentile of U.S. natural gas plants. By 2025 generation it ranks 543rd of 12,977 U.S. plants.
Latest data: August 2026; data loaded .
How hard does the Cunningham plant run compared with other natural gas plants?
The Cunningham plant had a capacity factor of 52% in 2025 on 390 MW of net summer capacity, the 72nd percentile of the 1,236 U.S. natural gas plants with at least 20 MW. The typical natural gas plant reached 22%. That equals about 191 days at full output out of 365.
0%Shaded: the middle half of natural gas plants. Mark: this plant.105%
| Measure | Capacity factor |
|---|---|
| Cunningham | 52% |
| Natural gas plants, 75th percentile | 56% |
| Natural gas plants, median | 22% |
| Natural gas plants, 25th percentile | 6% |
Source: EIA Forms EIA-860 and EIA-923, 2025. Capacity factor is net generation divided by capacity times the hours in the year, using net summer capacity, as EIA does. Values above 105% are left out of the comparison.
Is the Cunningham plant generating more or less than last year?
Generation at Cunningham rose 2.7% from 2024 to 2025, from 1,745,493 MWh to 1,792,031 MWh. Through August 2026 it is running 4.3% behind the same months of 2025.
| Period | MWh |
|---|---|
| 2024 | 1,745,493 |
| 2025 | 1,792,031 |
| 2026 through August | 1,155,436 |
| 2025, same months | 1,206,982 |
Monthly generation, Jan 2024 to Aug 2026
| Month | MWh |
|---|---|
| August 2026 | 219,129 |
| July 2026 | 183,458 |
| June 2026 | 127,366 |
| May 2026 | 119,176 |
| April 2026 | 82,436 |
| March 2026 | 97,220 |
| February 2026 | 135,318 |
| January 2026 | 191,333 |
| December 2025 | 141,377 |
| November 2025 | 133,923 |
| October 2025 | 140,153 |
| September 2025 | 169,596 |
| August 2025 | 212,721 |
| July 2025 | 85,184 |
| June 2025 | 160,085 |
| May 2025 | 215,824 |
| April 2025 | 96,063 |
| March 2025 | 105,813 |
| February 2025 | 164,443 |
| January 2025 | 166,849 |
| December 2024 | 135,671 |
| November 2024 | 144,714 |
| October 2024 | 156,003 |
| September 2024 | 136,836 |
| August 2024 | 195,951 |
| July 2024 | 160,411 |
| June 2024 | 197,800 |
| May 2024 | 124,753 |
| April 2024 | 146,160 |
| March 2024 | 169,944 |
| February 2024 | 84,106 |
| January 2024 | 93,144 |
Source: EIA Form EIA-923, through August 2026.
Source: EIA Forms EIA-860 and EIA-923, 2025. State totals add up the plants in these forms, including net use by storage.
How old are the generators at the Cunningham plant, and when do they retire?
3 operable generators total 444 MW, with an average age of 41 years weighted by capacity at the end of 2025. 444 MW, 100% of operable capacity, has a planned retirement, the first in 2027. 1 has already retired, totalling 75 MW.
| Entered service | Units | MW | Share | Planned retirement |
|---|---|---|---|---|
| 1960s | 1 | 190 | 43% | 2027 |
| 1990s | 2 | 254 | 57% | 2040 |
| Year | Units | MW retiring | Share of plant |
|---|---|---|---|
| 2027 | 1 | 190 | 43% |
| 2040 | 2 | 254 | 57% |
Every generator, 4 in all
| Unit | Status | Technology | MW | In service | Planned retirement |
|---|---|---|---|---|---|
| 2 | Operating | Natural Gas Steam Turbine | 190 | 1965 | 2027 |
| 3 | Operating | Natural Gas Fired Combustion Turbine | 127 | 1998 | 2040 |
| 4 | Operating | Natural Gas Fired Combustion Turbine | 127 | 1998 | 2040 |
| 1 | Retired | Natural Gas Steam Turbine | 75 | 1957 | 2024 |
Source: EIA Form EIA-860, Generator, 2025 final.
Who owns the Cunningham plant?
EIA lists no joint owners for Cunningham. Southwestern Public Service Co operates the plant.
Source: EIA Form EIA-860, Owner, 2025 final.
What does Southwestern Public Service Co charge homes?
Southwestern Public Service Co, the operator of Cunningham, had an average residential price of 12.86¢ per kWh and an average bill of $125 a month in 2025, 13% below the New Mexico average of 14.85¢.
| Measure | Price | Monthly bill | Against New Mexico |
|---|---|---|---|
| Southwestern Public Service Co | 12.86¢ | $125 | 13% lower |
| New Mexico average | 14.85¢ | $95 | |
| U.S. average | 17.23¢ | $151 | 16% higher |
Source: EIA Form EIA-861, final 2025. Average price is revenue divided by sales. It is what the seller's customers paid on average, not the cost of this plant's output.
Where is the Cunningham plant?
Cunningham is in Hobbs, Lea County, New Mexico, at 32.7131° N, 103.3533° W. It sits in the Southwest Power Pool balancing area (NERC region MRO).
Source: EIA Form EIA-860, Plant, 2025 final.
Which natural gas plants in New Mexico are similar in size?
New Mexico has 18 operable natural gas plants with 3,653 MW of capacity, and Cunningham's 444 MW is 12% of that.
| Plant | County | MW | 2025 MWh |
|---|---|---|---|
| Hobbs Generating Station | Lea | 682 | 3,284,123 |
| Luna Energy Facility | Luna | 650 | 1,662,177 |
| Cunningham | Lea | 444 | 1,792,031 |
| Rio Grande | Dona Ana | 348 | 789,889 |
| Afton Generating Station | Dona Ana | 287 | 460,051 |
Source: EIA Forms EIA-860 and EIA-923, 2025.