Skip to main content
RateWatt

Natural gas power plant, Ohio

Richland natural gas power plant, Ohio

Richland (OH) is a 450 MW power plant, 435 MW of it natural gas, in Defiance County, Ohio, operated by Richland-Stryker Generation LLC, and it generated 367,454 MWh in 2025 (Forms EIA-860 and EIA-923). That is 0.3% of the generation reported in Ohio, and its capacity factor sits at the 38th percentile of U.S. natural gas plants. By 2025 generation it ranks 1,700th of 12,977 U.S. plants.

Latest data: August 2026; data loaded .

450 MWNameplate capacity
12%Capacity factor, 2025, natural gas units, 38th percentile, on 358 MW net summer
0.3%Of OH generation, 2025
28 yearsAverage generator age, by MW

How hard does the Richland (OH) plant run compared with other natural gas plants?

The Richland (OH) plant's natural gas units had a capacity factor of 12% in 2025 on 358 MW of net summer capacity, the 38th percentile of the 1,236 U.S. natural gas plants with at least 20 MW. The typical natural gas plant reached 22%. That equals about 43 days at full output out of 365.

0%Shaded: the middle half of natural gas plants. Mark: this plant.105%

Capacity factor, 2025
MeasureCapacity factor
Richland (OH)12%
Natural gas plants, 75th percentile56%
Natural gas plants, median22%
Natural gas plants, 25th percentile6%

Source: EIA Forms EIA-860 and EIA-923, 2025. Capacity factor is net generation divided by capacity times the hours in the year, using net summer capacity, as EIA does, for its natural gas generators only. Values above 105% are left out of the comparison.

Is the Richland (OH) plant generating more or less than last year?

Generation at Richland (OH) rose 12.3% from 2024 to 2025, from 327,320 MWh to 367,454 MWh.

Net generation by period
PeriodMWh
2024327,320
2025367,454
Monthly generation, Jan 2024 to Dec 2025
MonthMWh
December 202510,074
November 20256,213
October 202534,048
September 202526,361
August 202528,224
July 202550,712
June 202535,290
May 20259,145
April 202531,922
March 202532,368
February 202555,386
January 202547,711
December 202410,365
November 202422,066
October 202423,232
September 202416,999
August 202425,000
July 20248,898
June 20246,589
May 202415,812
April 202460,722
March 202478,384
February 202422,814
January 202436,440

Source: EIA Form EIA-923, through August 2026.

How much of Ohio's electricity comes from the Richland (OH) plant?

Richland (OH) made 0.3% of the 145,060,499 MWh reported by Ohio plants in 2025, from 1.3% of the state's 34,392 MW of capacity. Its share of output is smaller than its share of capacity. By capacity it is the 28th largest of 215 plants in Ohio, the 793rd largest of 14,327 in the U.S. and the 494th largest of 1,962 natural gas plants on its natural gas units alone. By 2025 generation it is the 36th largest of 187 generating plants in the state.

Richland (OH) within Ohio, 2025
MeasureThis plantOhioShare
Capacity (MW)45034,3921.3%
Generation (MWh)367,454145,060,4990.3%
Natural gas capacity (MW)43518,3982.4%

Source: EIA Forms EIA-860 and EIA-923, 2025. State totals add up the plants in these forms, including net use by storage.

How old are the generators at the Richland (OH) plant, and when do they retire?

6 operable generators total 450 MW, with an average age of 28 years weighted by capacity at the end of 2025. No operable generator has a planned retirement date on Form EIA-860.

Operable generators by decade in service
Entered serviceUnitsMWSharePlanned retirement
1960s34510%none reported
2000s340590%none reported
Every generator, 6 in all
UnitStatusTechnologyMWIn servicePlanned retirement
1OperatingPetroleum Liquids151965n/a
2OperatingNatural Gas Fired Combustion Turbine151966n/a
3OperatingNatural Gas Fired Combustion Turbine151966n/a
4OperatingNatural Gas Fired Combustion Turbine1352001n/a
5OperatingNatural Gas Fired Combustion Turbine1352001n/a
6OperatingNatural Gas Fired Combustion Turbine1352001n/a

Source: EIA Form EIA-860, Generator, 2025 final.

Who owns the Richland (OH) plant?

EIA lists no joint owners for Richland (OH). Richland-Stryker Generation LLC operates the plant.

Source: EIA Form EIA-860, Owner, 2025 final.

What fuels does the Richland (OH) plant use?

Richland (OH) has capacity on 2 fuels: 97% natural gas and 3% petroleum. In 2025, natural gas made 100% of its output.

Capacity and 2025 generation by fuel
FuelMWShare2025 MWh
Natural gas43596.7%367,360
Petroleum153.3%94

Source: EIA Forms EIA-860 and EIA-923, 2025.

Where is the Richland (OH) plant?

Richland (OH) is in Defiance, Defiance County, Ohio, at 41.3052° N, 84.3346° W. It sits in the PJM Interconnection, LLC balancing area (NERC region RFC).

Source: EIA Form EIA-860, Plant, 2025 final.

Which natural gas plants in Ohio are similar in size?

Ohio has 47 operable natural gas plants with 18,398 MW of capacity, and Richland (OH)'s 435 MW is 2% of that.

Natural gas plants in Ohio around this size
PlantCountyMW2025 MWh
Darby Power, LLCPickaway564536,879
Middletown Energy CenterButler5443,144,914
Long Ridge Energy GenerationMonroe5223,808,688
Richland (OH)Defiance435367,360
West LorainLorain4251,299,162
Greenville Electric Generating StationDarke23681,026

Source: EIA Forms EIA-860 and EIA-923, 2025.