Skip to main content
RateWatt

Solar power plant, Illinois

Tilden Solar power plant, Illinois

Tilden Solar is a 150 MW solar power plant in Randolph County, Illinois, operated by Sol Systems, and it generated 25,874 MWh in 2025 (Forms EIA-860 and EIA-923). Its capacity factor sits at the 3rd percentile of U.S. solar plants. By 2025 generation it ranks 4,924th of 12,977 U.S. plants.

Latest data: August 2026; data loaded .

150 MWNameplate capacity
2%Capacity factor, 2025, 3rd percentile, on 150 MW net summer
4,924thU.S. rank by generation, 2025
Under 1 yearAverage generator age, by MW

How hard does the Tilden Solar plant run compared with other solar plants?

The Tilden Solar plant had a capacity factor of 2% in 2025 on 150 MW of net summer capacity, the 3rd percentile of the 1,298 U.S. solar plants with at least 20 MW. The typical solar plant reached 23%. That equals about 7 days at full output out of 365.

0%Shaded: the middle half of solar plants. Mark: this plant.105%

Capacity factor, 2025
MeasureCapacity factor
Tilden Solar2%
Solar plants, 75th percentile27%
Solar plants, median23%
Solar plants, 25th percentile20%

Source: EIA Forms EIA-860 and EIA-923, 2025. Capacity factor is net generation divided by capacity times the hours in the year, using net summer capacity, as EIA does. Values above 105% are left out of the comparison.

Is the Tilden Solar plant generating more or less than last year?

Tilden Solar generated 25,874 MWh in 2025; EIA reports no 2024 total to compare.

Net generation by period
PeriodMWh
2024n/a
202525,874
2026 through August238,853
Monthly generation, Nov 2025 to Aug 2026
MonthMWh
August 202636,631
July 202637,226
June 202637,768
May 202630,920
April 202632,542
March 202627,083
February 202620,124
January 202616,559
December 20259,963
November 202515,911

Source: EIA Form EIA-923, through August 2026.

How much of Illinois' electricity comes from the Tilden Solar plant?

Tilden Solar made 0.0% of the 191,710,915 MWh reported by Illinois plants in 2025, from 0.3% of the state's 52,515 MW of capacity. Its share of output is smaller than its share of capacity. By capacity it is the 81st largest of 602 plants in Illinois, the 1,967th largest of 14,327 in the U.S. and the 310th largest of 7,223 solar plants. By 2025 generation it is the 129th largest of 531 generating plants in the state.

Tilden Solar within Illinois, 2025
MeasureThis plantIllinoisShare
Capacity (MW)15052,5150.3%
Generation (MWh)25,874191,710,9150.0%
Solar capacity (MW)1504,3873.4%

Source: EIA Forms EIA-860 and EIA-923, 2025. State totals add up the plants in these forms, including net use by storage.

How old are the generators at the Tilden Solar plant, and when do they retire?

1 operable generator totals 150 MW, with an average age of 0 years weighted by capacity at the end of 2025. No operable generator has a planned retirement date on Form EIA-860.

Operable generators by decade in service
Entered serviceUnitsMWSharePlanned retirement
2020s1150100%none reported
Every generator, 1 in all
UnitStatusTechnologyMWIn servicePlanned retirement
TILDNOperatingSolar Photovoltaic1502025n/a

Source: EIA Form EIA-860, Generator, 2025 final.

Who owns the Tilden Solar plant?

EIA lists no joint owners for Tilden Solar. Sol Systems operates the plant.

Source: EIA Form EIA-860, Owner, 2025 final.

Where is the Tilden Solar plant?

Tilden Solar is in Coulterville, Randolph County, Illinois, at 38.1907° N, 89.6841° W. It sits in the Midcontinent Independent Transmission System Operator, Inc. balancing area (NERC region SERC).

Source: EIA Form EIA-860, Plant, 2025 final.

Which solar plants in Illinois are similar in size?

Illinois has 406 operable solar plants with 4,387 MW of capacity, and Tilden Solar's 150 MW is 3% of that.

Solar plants in Illinois around this size
PlantCountyMW2025 MWh
Boomtown Renewable Energy CenterWhite150286,304
Cass County Renewable Energy CenterCass150331,772
Pleasantville Solar ParkFulton15048,205
Tilden SolarRandolph15025,874
Big River SolarWhite149314,717
Wolf Run SolarMorgan140314,470
Eldorado Solar IISaline12039,394

Source: EIA Forms EIA-860 and EIA-923, 2025.