Skip to main content
RateWatt

Hydro power plant, North Carolina

Walters hydroelectric power plant, North Carolina

Walters is a 108 MW hydro power plant in Haywood County, North Carolina, operated by Duke Energy Progress-(NC), and it generated 289,085 MWh in 2025 (Forms EIA-860 and EIA-923). That is 0.2% of the generation reported in North Carolina, and its capacity factor sits at the 41st percentile of U.S. hydro plants. By 2025 generation it ranks 2,022nd of 12,977 U.S. plants.

Latest data: August 2026; data loaded .

108 MWNameplate capacity
29%Capacity factor, 2025, 41st percentile, on 112 MW net summer
0.2%Of NC generation, 2025
95 yearsAverage generator age, by MW

How hard does the Walters plant run compared with other hydro plants?

The Walters plant had a capacity factor of 29% in 2025 on 112 MW of net summer capacity, the 41st percentile of the 427 U.S. hydro plants with at least 20 MW. The typical hydro plant reached 33%. That equals about 108 days at full output out of 365.

0%Shaded: the middle half of hydro plants. Mark: this plant.105%

Capacity factor, 2025
MeasureCapacity factor
Walters29%
Hydro plants, 75th percentile44%
Hydro plants, median33%
Hydro plants, 25th percentile22%

Source: EIA Forms EIA-860 and EIA-923, 2025. Capacity factor is net generation divided by capacity times the hours in the year, using net summer capacity, as EIA does. Values above 105% are left out of the comparison.

Is the Walters plant generating more or less than last year?

Walters generated 289,085 MWh in 2025; EIA reports no 2024 total to compare. 2024 has output for only 9 months, so the two years are not compared.

3 months show net generation below zero, when the plant used more power than it sent out, so the months are listed below rather than charted.

Net generation by period
PeriodMWh
2024275,305
2025289,085
Monthly generation, Jan 2024 to Dec 2025
MonthMWh
December 202518,099
November 202513,233
October 202514,293
September 202516,040
August 202530,724
July 202519,190
June 202524,928
May 202540,753
April 202542,045
March 202539,634
February 202530,231
January 2025-85
December 2024-77
November 2024-45
October 20240
September 20248,715
August 202413,175
July 202414,830
June 202421,042
May 202442,715
April 202434,347
March 202451,130
February 202439,750
January 202449,723

Source: EIA Form EIA-923, through August 2026.

How much of North Carolina's electricity comes from the Walters plant?

Walters made 0.2% of the 134,194,434 MWh reported by North Carolina plants in 2025, from 0.3% of the state's 39,933 MW of capacity. Its share of output is smaller than its share of capacity. By capacity it is the 38th largest of 928 plants in North Carolina, the 2,462nd largest of 14,327 in the U.S. and the 143rd largest of 1,393 hydro plants. By 2025 generation it is the 28th largest of 872 generating plants in the state.

Walters within North Carolina, 2025
MeasureThis plantNorth CarolinaShare
Capacity (MW)10839,9330.3%
Generation (MWh)289,085134,194,4340.2%
Hydro capacity (MW)1081,7926.0%

Source: EIA Forms EIA-860 and EIA-923, 2025. State totals add up the plants in these forms, including net use by storage.

How old are the generators at the Walters plant, and when do they retire?

3 operable generators total 108 MW, with an average age of 95 years weighted by capacity at the end of 2025. No operable generator has a planned retirement date on Form EIA-860.

Operable generators by decade in service
Entered serviceUnitsMWSharePlanned retirement
1930s3108100%none reported
Every generator, 3 in all
UnitStatusTechnologyMWIn servicePlanned retirement
1OperatingConventional Hydroelectric361930n/a
2OperatingConventional Hydroelectric361930n/a
3OperatingConventional Hydroelectric361930n/a

Source: EIA Form EIA-860, Generator, 2025 final.

Who owns the Walters plant?

EIA lists no joint owners for Walters. Duke Energy Progress-(NC) operates the plant.

Source: EIA Form EIA-860, Owner, 2025 final.

What does Duke Energy Progress charge homes?

Duke Energy Progress, the operator of Walters, had an average residential price of 15.19¢ per kWh and an average bill of $159 a month in 2025, 9% above the North Carolina average of 14.00¢.

Average residential price and bill, 2025
MeasurePriceMonthly billAgainst North Carolina
Duke Energy Progress15.19¢$1599% higher
North Carolina average14.00¢$146
U.S. average17.23¢$15123% higher

Source: EIA Form EIA-861, final 2025. Average price is revenue divided by sales. It is what the seller's customers paid on average, not the cost of this plant's output.

Where is the Walters plant?

Walters is in Waterville, Haywood County, North Carolina, at 35.6946° N, 83.0503° W. It sits in the Duke Energy Progress East balancing area (NERC region SERC).

Source: EIA Form EIA-860, Plant, 2025 final.

Which hydro plants in North Carolina are similar in size?

North Carolina has 37 operable hydro plants with 1,792 MW of capacity, and Walters' 108 MW is 6% of that.

Hydro plants in North Carolina around this size
PlantCountyMW2025 MWh
GastonHalifax178225,599
CheoahGraham140472,350
Narrows (NC)Stanly109362,757
WaltersHaywood108289,085
Roanoke RapidsHalifax100187,211
TilleryMontgomery84117,676
Mountain IslandGaston6089,991

Source: EIA Forms EIA-860 and EIA-923, 2025.