Skip to main content
RateWatt

Solar power plant, New Mexico

San Juan Solar I power plant, New Mexico

San Juan Solar I is a 300 MW power plant, 200 MW of it solar, in San Juan County, New Mexico, operated by San Juan Solar I, LLC, and it generated 484,488 MWh in 2025 (Forms EIA-860 and EIA-923). That is 1.2% of the generation reported in New Mexico, and its capacity factor sits at the 86th percentile of U.S. solar plants. By 2025 generation it ranks 1,370th of 12,977 U.S. plants.

Latest data: August 2026; data loaded .

300 MWNameplate capacity
29%Capacity factor, 2025, solar units, 86th percentile, on 200 MW net summer
1.2%Of NM generation, 2025
1 yearAverage generator age, by MW

How hard does the San Juan Solar I plant run compared with other solar plants?

The San Juan Solar I plant's solar units had a capacity factor of 29% in 2025 on 200 MW of net summer capacity, the 86th percentile of the 1,298 U.S. solar plants with at least 20 MW. The typical solar plant reached 23%. That equals about 105 days at full output out of 365.

0%Shaded: the middle half of solar plants. Mark: this plant.105%

Capacity factor, 2025
MeasureCapacity factor
San Juan Solar I29%
Solar plants, 75th percentile27%
Solar plants, median23%
Solar plants, 25th percentile20%

Source: EIA Forms EIA-860 and EIA-923, 2025. Capacity factor is net generation divided by capacity times the hours in the year, using net summer capacity, as EIA does, for its solar generators only. Values above 105% are left out of the comparison.

Is the San Juan Solar I plant generating more or less than last year?

San Juan Solar I generated 484,488 MWh in 2025; EIA reports no 2024 total to compare. Through August 2026 it is running 12.2% ahead of the same months of 2025. 2024 has output for only 2 months, so the two years are not compared.

1 month shows net generation below zero, when the plant used more power than it sent out, so the months are listed below rather than charted.

Net generation by period
PeriodMWh
202446,069
2025484,488
2026 through August389,065
2025, same months346,655
Monthly generation, Oct 2024 to Aug 2026
MonthMWh
August 202647,706
July 202657,640
June 202657,270
May 202659,279
April 202651,291
March 202651,559
February 202633,032
January 202631,288
December 202527,825
November 202528,131
October 202540,101
September 202541,776
August 202552,735
July 202556,169
June 202558,612
May 202544,213
April 202542,236
March 202531,721
February 202533,265
January 202527,704
December 202425,900
November 202420,516
October 2024-347

Source: EIA Form EIA-923, through August 2026.

How much of New Mexico's electricity comes from the San Juan Solar I plant?

San Juan Solar I made 1.2% of the 39,178,246 MWh reported by New Mexico plants in 2025, from 2.2% of the state's 13,801 MW of capacity. Its share of output is smaller than its share of capacity. By capacity it is the 11th largest of 161 plants in New Mexico, the 1,045th largest of 14,327 in the U.S. and the 170th largest of 7,223 solar plants on its solar units alone. By 2025 generation it is the 24th largest of 151 generating plants in the state.

San Juan Solar I within New Mexico, 2025
MeasureThis plantNew MexicoShare
Capacity (MW)30013,8012.2%
Generation (MWh)484,48839,178,2461.2%
Solar capacity (MW)2002,9026.9%

Source: EIA Forms EIA-860 and EIA-923, 2025. State totals add up the plants in these forms, including net use by storage.

How old are the generators at the San Juan Solar I plant, and when do they retire?

2 operable generators total 300 MW, with an average age of 1 year weighted by capacity at the end of 2025. No operable generator has a planned retirement date on Form EIA-860.

Operable generators by decade in service
Entered serviceUnitsMWSharePlanned retirement
2020s2300100%none reported
Every generator, 2 in all
UnitStatusTechnologyMWIn servicePlanned retirement
SANSOperatingSolar Photovoltaic2002024n/a
SJSSOperatingBatteries1002024n/a

Source: EIA Form EIA-860, Generator, 2025 final.

Who owns the San Juan Solar I plant?

EIA lists no joint owners for San Juan Solar I. San Juan Solar I, LLC operates the plant.

Source: EIA Form EIA-860, Owner, 2025 final.

What fuels does the San Juan Solar I plant use?

San Juan Solar I has capacity on 2 fuels: 67% solar and 33% battery and pumped storage. In 2025, solar made 104% of its output.

Capacity and 2025 generation by fuel
FuelMWShare2025 MWh
Solar20066.7%503,209
Battery and pumped storage10033.3%-18,721

Source: EIA Forms EIA-860 and EIA-923, 2025.

Where is the San Juan Solar I plant?

San Juan Solar I is in Kirtland, San Juan County, New Mexico, at 36.8425° N, 108.3514° W. It sits in the Public Service Company of New Mexico balancing area (NERC region WECC).

Source: EIA Form EIA-860, Plant, 2025 final.

Which solar plants in New Mexico are similar in size?

New Mexico has 101 operable solar plants with 2,902 MW of capacity, and San Juan Solar I's 200 MW is 7% of that.

Solar plants in New Mexico around this size
PlantCountyMW2025 MWh
Arroyo Solar Energy Storage HybridMcKinley300697,111
Atrisco Solar LLCBernalillo300717,749
San Juan Solar ISan Juan200503,209
Escalante (NM)McKinley200526,335
Sky Ranch SolarValencia190510,831
Milagro Solar IDona Ana150279,072

Source: EIA Forms EIA-860 and EIA-923, 2025.