Skip to main content
RateWatt

Solar power plant, California

Scarlet II Hybrid solar power plant, California

Scarlet II Hybrid is a 350 MW power plant, 200 MW of it solar, in Fresno County, California, operated by EDPR Scarlet II LLC, and it generated 385,106 MWh in 2025 (Forms EIA-860 and EIA-923). That is 0.2% of the generation reported in California, and its capacity factor sits at the 49th percentile of U.S. solar plants. By 2025 generation it ranks 1,636th of 12,977 U.S. plants.

Latest data: August 2026; data loaded .

350 MWNameplate capacity
23%Capacity factor, 2025, solar units, 49th percentile, on 200 MW net summer
0.2%Of CA generation, 2025
1 yearAverage generator age, by MW

How hard does the Scarlet II Hybrid plant run compared with other solar plants?

The Scarlet II Hybrid plant's solar units had a capacity factor of 23% in 2025 on 200 MW of net summer capacity, the 49th percentile of the 1,298 U.S. solar plants with at least 20 MW. The typical solar plant reached 23%. That equals about 84 days at full output out of 365.

0%Shaded: the middle half of solar plants. Mark: this plant.105%

Capacity factor, 2025
MeasureCapacity factor
Scarlet II Hybrid23%
Solar plants, 75th percentile27%
Solar plants, median23%
Solar plants, 25th percentile20%

Source: EIA Forms EIA-860 and EIA-923, 2025. Capacity factor is net generation divided by capacity times the hours in the year, using net summer capacity, as EIA does, for its solar generators only. Values above 105% are left out of the comparison.

Is the Scarlet II Hybrid plant generating more or less than last year?

Scarlet II Hybrid generated 385,106 MWh in 2025; EIA reports no 2024 total to compare. Through August 2026 it is running 11.4% behind the same months of 2025. 2024 has output for only 1 month, so the two years are not compared.

Net generation by period
PeriodMWh
20249,038
2025385,106
2026 through August266,103
2025, same months300,318
Monthly generation, Dec 2024 to Aug 2026
MonthMWh
August 202632,110
July 202639,916
June 202650,715
May 202640,320
April 202638,308
March 202635,028
February 202618,686
January 202611,020
December 20255,746
November 202511,641
October 202534,585
September 202532,816
August 202550,002
July 202554,286
June 202554,547
May 202543,331
April 202526,364
March 202524,792
February 202522,228
January 202524,768
December 20249,038

Source: EIA Form EIA-923, through August 2026.

How much of California's electricity comes from the Scarlet II Hybrid plant?

Scarlet II Hybrid made 0.2% of the 204,542,898 MWh reported by California plants in 2025, from 0.3% of the state's 107,433 MW of capacity. Its share of output is smaller than its share of capacity. By capacity it is the 61st largest of 1,877 plants in California, the 923rd largest of 14,327 in the U.S. and the 175th largest of 7,223 solar plants on its solar units alone. By 2025 generation it is the 119th largest of 1,608 generating plants in the state.

Scarlet II Hybrid within California, 2025
MeasureThis plantCaliforniaShare
Capacity (MW)350107,4330.3%
Generation (MWh)385,106204,542,8980.2%
Solar capacity (MW)20024,6630.8%

Source: EIA Forms EIA-860 and EIA-923, 2025. State totals add up the plants in these forms, including net use by storage.

How old are the generators at the Scarlet II Hybrid plant, and when do they retire?

2 operable generators total 350 MW, with an average age of 1 year weighted by capacity at the end of 2025. No operable generator has a planned retirement date on Form EIA-860.

Operable generators by decade in service
Entered serviceUnitsMWSharePlanned retirement
2020s2350100%none reported
Every generator, 2 in all
UnitStatusTechnologyMWIn servicePlanned retirement
GEN03OperatingSolar Photovoltaic2002024n/a
GEN04OperatingBatteries1502024n/a

Source: EIA Form EIA-860, Generator, 2025 final.

Who owns the Scarlet II Hybrid plant?

EIA lists no joint owners for Scarlet II Hybrid. EDPR Scarlet II LLC operates the plant.

Source: EIA Form EIA-860, Owner, 2025 final.

What fuels does the Scarlet II Hybrid plant use?

Scarlet II Hybrid has capacity on 2 fuels: 57% solar and 43% battery and pumped storage. In 2025, solar made 105% of its output.

Capacity and 2025 generation by fuel
FuelMWShare2025 MWh
Solar20057.1%403,487
Battery and pumped storage15042.9%-18,381

Source: EIA Forms EIA-860 and EIA-923, 2025.

Where is the Scarlet II Hybrid plant?

Scarlet II Hybrid is in Cantua Creek, Fresno County, California, at 36.6037° N, 120.3757° W. It sits in the California Independent System Operator balancing area (NERC region WECC).

Source: EIA Form EIA-860, Plant, 2025 final.

Which solar plants in California are similar in size?

California has 934 operable solar plants with 24,663 MW of capacity, and Scarlet II Hybrid's 200 MW is 1% of that.

Solar plants in California around this size
PlantCountyMW2025 MWh
Scarlet Solar (CA)Fresno200488,817
Sandrini Solar 200Kern200411,296
Victory PassRiverside200585,624
Scarlet II HybridFresno200403,487
Luna ValleyFresno200134,619
Imperial Valley Solar, LLCImperial200441,675
Golden Field Solar III, LLCKern192548,125

Source: EIA Forms EIA-860 and EIA-923, 2025.