Edwards Sanborn E1A is a 293 MW power plant, 149 MW of it solar, in Kern County, California, operated by Terra-Gen Operating Co-Hybrid, and it generated 332,363 MWh in 2025 (Forms EIA-860 and EIA-923). That is 0.2% of the generation reported in California, and its capacity factor sits at the 75th percentile of U.S. solar plants. By 2025 generation it ranks 1,838th of 12,977 U.S. plants.

Latest data: August 2026; data loaded .

293 MWNameplate capacity
27%Capacity factor, 2025, solar units, 75th percentile, on 149 MW net summer
0.2%Of CA generation, 2025
3 yearsAverage generator age, by MW

How hard does the Edwards Sanborn E1A plant run compared with other solar plants?

The Edwards Sanborn E1A plant's solar units had a capacity factor of 27% in 2025 on 149 MW of net summer capacity, the 75th percentile of the 1,298 U.S. solar plants with at least 20 MW. The typical solar plant reached 23%. That equals about 97 days at full output out of 365.

0%Shaded: the middle half of solar plants. Mark: this plant.105%

Capacity factor, 2025
MeasureCapacity factor
Edwards Sanborn E1A27%
Solar plants, 75th percentile27%
Solar plants, median23%
Solar plants, 25th percentile20%

Source: EIA Forms EIA-860 and EIA-923, 2025. Capacity factor is net generation divided by capacity times the hours in the year, using net summer capacity, as EIA does, for its solar generators only. Values above 105% are left out of the comparison.

Is the Edwards Sanborn E1A plant generating more or less than last year?

Generation at Edwards Sanborn E1A rose 1.6% from 2024 to 2025, from 327,194 MWh to 332,363 MWh. Through August 2026 it is running 8.3% behind the same months of 2025.

Net generation by period
PeriodMWh
2024327,194
2025332,363
2026 through August226,158
2025, same months246,678
Monthly generation, Jan 2024 to Aug 2026
MonthMWh
August 202634,521
July 202635,191
June 202640,278
May 202634,036
April 202623,563
March 202625,274
February 202617,076
January 202616,219
December 202514,281
November 202515,183
October 202526,324
September 202529,897
August 202535,731
July 202540,806
June 202539,153
May 202537,442
April 202535,436
March 202521,358
February 202518,982
January 202517,770
December 202414,032
November 202417,662
October 202424,822
September 202429,350
August 202435,584
July 202437,074
June 202440,037
May 202440,442
April 202432,540
March 202422,702
February 202417,614
January 202415,335

Source: EIA Form EIA-923, through August 2026.

How much of California's electricity comes from the Edwards Sanborn E1A plant?

Edwards Sanborn E1A made 0.2% of the 204,542,898 MWh reported by California plants in 2025, from 0.3% of the state's 107,433 MW of capacity. Its share of output is smaller than its share of capacity. By capacity it is the 78th largest of 1,877 plants in California, the 1,111th largest of 14,327 in the U.S. and the 311th largest of 7,223 solar plants on its solar units alone. By 2025 generation it is the 149th largest of 1,608 generating plants in the state.

Edwards Sanborn E1A within California, 2025
MeasureThis plantCaliforniaShare
Capacity (MW)293107,4330.3%
Generation (MWh)332,363204,542,8980.2%
Solar capacity (MW)14924,6630.6%

Source: EIA Forms EIA-860 and EIA-923, 2025. State totals add up the plants in these forms, including net use by storage.

How old are the generators at the Edwards Sanborn E1A plant, and when do they retire?

2 operable generators total 293 MW, with an average age of 3 years weighted by capacity at the end of 2025. No operable generator has a planned retirement date on Form EIA-860.

Operable generators by decade in service
Entered serviceUnitsMWSharePlanned retirement
2020s2293100%none reported
Every generator, 2 in all
UnitStatusTechnologyMWIn servicePlanned retirement
BESSOperatingBatteries1442022n/a
PVOperatingSolar Photovoltaic1492022n/a

Source: EIA Form EIA-860, Generator, 2025 final.

Who owns the Edwards Sanborn E1A plant?

EIA lists no joint owners for Edwards Sanborn E1A. Terra-Gen Operating Co-Hybrid operates the plant.

Source: EIA Form EIA-860, Owner, 2025 final.

What fuels does the Edwards Sanborn E1A plant use?

Edwards Sanborn E1A has capacity on 2 fuels: 51% solar and 49% battery and pumped storage. In 2025, solar made 105% of its output.

Capacity and 2025 generation by fuel
FuelMWShare2025 MWh
Solar14950.9%347,607
Battery and pumped storage14449.1%-15,244

Source: EIA Forms EIA-860 and EIA-923, 2025.

Where is the Edwards Sanborn E1A plant?

Edwards Sanborn E1A is in Mojave, Kern County, California, at 34.9619° N, 118.1242° W. It sits in the California Independent System Operator balancing area (NERC region WECC).

Source: EIA Form EIA-860, Plant, 2025 final.

Which solar plants in California are similar in size?

California has 934 operable solar plants with 24,663 MW of capacity, and Edwards Sanborn E1A's 149 MW is 1% of that.

Solar plants in California around this size
PlantCountyMW2025 MWh
Fifth Standard Solar PV, LLC (Hybrid)Fresno150327,093
Baldy Mesa Solar & StorageSan Bernardino150303,251
Northern Orchard Solar PV, LLCKern150210,871
Edwards Sanborn E1AKern149347,607
Edwards Sanborn E4Kern149326,084
Imperial Solar Energy Center WestImperial149356,963
Edwards Sanborn 1CKern14837,973

Source: EIA Forms EIA-860 and EIA-923, 2025.